Description: Style AG70EPCG is a 70 durometer commercial grade EPDM gasketing material designed for applications that require a solid rubber material suitable for outdoor environments. 70 durometer commercial grade EPDM has a service temperature of -40°F to +220°F. Known by the chemical name ethylene propylene, 70 durometer commercial grade EPDM is formulated to meet the ASTM D2000 M1AA 706 standard. Style AG70EPCG provides excellent resistance to severe weather conditions, ozone, and oxidants.
Atlantic Gasket’s commercial grade EPDM is available in a wide range of durometers, ranging from as soft as 50 Durometer (AG50EPCG) to as hard as 70 Durometer (AG70EPCG) with standard durometers in between. Style AG70EPCG is available in the color black and can be manufactured in a wide range of standard thicknesses, ranging from as thin a 1/64" to as thick as 1/4", with custom thicknesses available upon request. 70 durometer commercial grade EPDM has a smooth finish and can be converted into rolls ranging from as narrow as 1/4 wide up to 48" in width. Custom widths can be manufactured upon request. Atlantic Gasket has the ability to die-cut or waterjet cut 70 durometer commercial grade EPDM to meet your exact requirements.
Specifications
ASTM D2000 M1AA 706
Physical Property | Unit of Measure | Typical Values |
---|---|---|
DUROMETER | SHORE A | 70 +/- 5 |
TENSILE STRENGTH | psi | 870 (min) |
ELONGATION | % | 150 (min) |
LOW TEMPERATURE | °F °C |
-40°F -40°C |
HIGH TEMPERATURE | °F °C |
220°F 104°C |
COLOR | N/A | BLACK |
General Characteristics of EPDM Rubber: | |
---|---|
Dielectric Strength | Outstanding |
Dilute Acid Resistance | Outstanding |
Resistance to Oil and Gasoline | Poor |
Resistance to Water Absorption | Excellent |
Resistance to Oxidation | Excellent |
Resistance to Ozone | Outstanding |
Resistance to Sunlight Aging | Outstanding |
Solvent Resistance – Oxygenated (Ketones, etc.) | Excellent |
Resistance to Chlorinated Hydrocarbons | Poor |